Level 1 sweep and inspection to the NFPA 211 annual standard - flue, crown, cap, and flashing checked and photographed
Chimney sweep logs do not sweep chimneys. They loosen some creosote - which then falls where a brush and vacuum still have to collect it.
Gelco Damper Repair: The Leesburg Owner’s Guide
A Gelco damper repair in Leesburg typically runs $280-$520 installed, depending on whether the throat plate, frame, or entire assembly needs replacement. We stock common Gelco damper parts on our trucks and can usually complete the repair in a single visit to your Leesburg home. Most homeowners notice the problem on the first cold night in October or November, when they reach for the damper handle and find it stuck, loose, or hanging at an angle that won’t seal.
We’ve been fixing Gelco dampers across Leesburg since the early 2000s, back when many of the brick colonials near Morven Park were getting their first major chimney overhauls. The Gelco units we see most often were installed in the 1990s and early 2000s, and they’re built to last - but the cast-iron throat plates do eventually crack from thermal cycling, and the stainless pivot pins corrode in our wet Virginia winters. Tell me what you are burning and how often, and I can tell you what your chimney looks like before I even climb up.
Which Gelco Models This Applies To
Gelco made several damper lines over the years, and the part you need depends on which generation is sitting in your flue. The most common in Leesburg homes is the Gelco cast-iron throat damper, typically found in 8″×13″ or 13″×13″ flue openings. These have a rectangular cast plate with a curved lip that seats against a matching frame mortared into the smoke chamber. Newer Gelco top-sealing dampers mount at the chimney crown and use a cable running down the flue - if your handle is on the side of the firebox, you have a throat damper; if it’s a rotary or pull-chain style near the hearth, it’s likely a top-sealer.
To identify your exact part, we need three things: the flue opening dimensions (measured inside the smoke chamber, not the firebox), the handle type and mounting position, and whether the original installer left a metal tag or stamp. Many Leesburg builders in the 1980s and 1990s used the Gelco 8-inch and 13-inch standard sizes, but we’ve also found custom 10″×15″ frames in the larger homes near Ida Lee Park. OEM Gelco parts are still manufactured for most lines, though some older cast-iron frames have been superseded by stainless equivalents that outlast the original. We carry both OEM and professional-grade aftermarket options from our regular suppliers - we’ll match what’s appropriate for your chimney and your budget.
Hearthstone Chimney Co. is an independent service provider with no affiliation to Gelco. We source parts through the same wholesale channels that supply chimney professionals nationwide.
Signs Your Gelco Damper Repair Is Failing
- The handle turns but the plate doesn’t move. The pivot pin has sheared or the linkage has slipped off its catch. This is the most common Gelco failure we see in Leesburg, especially in homes that burn oak or hickory - the intense heat cycles fatigue the pin faster than softer woods would.
- You feel a cold draft even when the damper is “closed.” The cast-iron throat plate has cracked or warped, leaving a gap that lets conditioned air escape year-round. In Leesburg’s older homes with balloon framing, this draft can pull from the walls as well as the chimney.
- The plate is stuck open or rusted in place. Moisture from chimney leaks or condensation has seized the mechanism. Our wet Virginia springs accelerate this - we’ve found dampers frozen solid after just one season of minor crown deterioration.
- Soot or smoke stains above the firebox. A damper that won’t open fully restricts draft, causing smoke to spill into the room. With Gelco throat dampers, the plate can drop slightly out of track without the homeowner noticing until the first smoky fire.
- The handle is loose or the mounting bracket has pulled away from the masonry. The anchor bolts have corroded or the surrounding brick has softened. This is repairable if caught early, but left alone, the bracket can fall into the firebox during use.
Replacement Cost & What’s Included
| Repair Type | Typical Range in Leesburg |
|---|---|
| Gelco pivot pin / linkage repair | $280-$360 |
| Cast-iron throat plate replacement (OEM or stainless equivalent) | $340-$460 |
| Full damper assembly replacement (plate + frame) | $420-$520 |
| Top-sealing Gelco damper conversion | $680-$890 |
What drives the range: accessibility of the smoke chamber (some Leesburg chimneys have tight shoulders that add labor), whether the frame is salvageable, and whether we find secondary issues like a cracked smoke shelf or deteriorated mortar. Every repair starts with our Level-2 camera inspection - photos you can see, a plain-English verdict - so you know exactly what failed and why. The price we quote is the price on the invoice. No surprises. All Gelco damper work carries our 90-Day Done Right Promise in writing: if it’s not right, we come back and make it right, no paperwork and no arguing.
DIY or Call Us?
There’s a safe middle ground here, and then there’s where DIY stops.
What you can check yourself: whether the handle is actually connected to anything (shine a flashlight up past the damper and watch while someone works the handle), whether debris or a bird nest is blocking the track, and whether the plate sits flat when closed. A homeowner with a flashlight and a mirror can spot obvious problems.
What you should not attempt: removing a stuck cast-iron plate, drilling out corroded pivot pins, or working inside the smoke chamber. The throat damper sits above the firebox in a confined space with sharp metal edges and loose mortar that can shower into your eyes. More importantly, a misaligned replacement plate can leave gaps that allow carbon monoxide to enter living space or creosote to accumulate in hidden pockets. We’ve been called to Leesburg homes where a well-meaning owner wedged a plate in crooked, creating a fire hazard they couldn’t see. The camera inspection is part of our standard repair - we document the before, the install, and the after. Done right, and we stand behind it.
Call (571) 701-7519 when you’re ready. A live person answers, 24 hours a day.
FAQs
A properly installed Gelco cast-iron throat damper typically lasts 20-30 years with regular use, though we’ve seen them fail in 15 years in homes that burn green or unseasoned wood. Leesburg’s freeze-thaw cycles and humid summers accelerate corrosion on the pivot hardware, so the mechanism often fails before the plate itself cracks. Annual inspection catches this early. Call (571) 701-7519 for a free estimate.
Sometimes. A sheared pivot pin or detached linkage can often be rebuilt if the cast-iron plate and frame are intact and properly seated. If the plate is cracked, warped, or eroded thin at the edges, replacement is the only safe option - we won’t patch a damper that can’t seal reliably. We’ll show you the camera footage and explain which category you’re in. Call (571) 701-7519 for a free estimate.
Most Gelco damper repairs we complete in Leesburg take 90 minutes to two hours from ladder set to final test burn. Full assembly replacements in tight smoke chambers may run closer to three hours. We arrive with parts on the truck for common sizes, so there’s no waiting for a second trip. Call (571) 701-7519 to schedule.
We carry pivot pins, linkage kits, and the most common throat plate sizes for 8″ and 13″ flues - the Gelco standards we encounter most in Loudoun County. Less common sizes or specialized top-sealing units we can source within 24-48 hours through our regular suppliers. We’ll confirm what’s needed during your inspection so there are no delays. Call (571) 701-7519 for a free estimate.
Written by Russell Haines, Owner, Hearthstone Chimney Co. at Hearthstone Chimney Co., serving Leesburg and nearby areas.





Before
After
Before
After
Before
After